Triglyceride, Body Fluid




Test Mnemonic

FTRIG

CPT Codes

  • 84478 - QTY (1)

Performing Laboratory

Cleveland Clinic Laboratories


Specimen Requirements

Volume Type Container Collect Temperature Transport Temperature Special Instructions
1 mLFluid, bodySterile container RefrigeratedViscous specimens will be rejected. Indicate source of fluid.

Minimum Specimen Requirements

Volume Type Container Collect Temperature Transport Temperature Special Instructions
0.5 mL     

Stability

Environmental Condition Description
Ambient5 days
Refrigerated7 days
FrozenUnacceptable

Days Performed

Sun - Sat

Turnaround Time

8 hours

Methodology

Name Description
Enzymatic 

Reference Range

Triglyceride, Body Fluid
Sex Age From Age To Type Range Range Unit
       Refer to Clinical Information 

Special Info

Indicate body fluid source/type.

Clinical Info

Synovial fluids: Synovial fluid triglycerides measurement may be useful in classifying various joint disorders. The reference range for adult synovial fluid triglycerides measurement is <= 40% of the concurrent plasma cholesterol measurement. Serous fluids: Serous fluid triglycerides measurement may be useful in classifying the effusion as chylous or nonchylous. A serous fluid triglycerides measurement >110 mg/dL is suggestive of a chylous effusion. A serous fluid triglycerides measurement <= 110 mg/dL is suggestive of a nonchylous effusion. Reference: 1. CLSI. Analysis of Body Fluids in Clinical Chemistry; Approved Guideline. CLSI document C49-A. Wayne, PA: Clinical Laboratory Standards Institute; 2007.