Herpesvirus 7 PCR, Quant, CSF




Test Mnemonic

HV7QNT

CPT Codes

  • 87799 - QTY (1)

LOINC ®

49399-9

Performing Laboratory

ViraCor-IBT Laboratories

FDA Category

Laboratory Developed Test


Specimen Requirements

Volume Type Container Collect Temperature Transport Temperature Special Instructions
2 mLCerebrospinal fluid (CSF)Sterile container FrozenFreeze immediately. Deliver to Cleveland Clinic Laboratories within 24 hours of collection. Specimen must be received by 12:00 noon EST on Fridays. Ship on dry ice.

Minimum Specimen Requirements

Volume Type Container Collect Temperature Transport Temperature Special Instructions
0.5 mL     

Stability

Environmental Condition Description
RefrigeratedUnacceptable
AmbientUnacceptable
Frozen96 hours

Days Performed

Mon - Sat

Turnaround Time

2 - 3 days

Methodology

Name Description
Polymerase Chain Reaction (PCR) 

Reference Range

Special Info

Deliver to Cleveland Clinic Laboratories within 24 hours of collection. Specimen must be received by 12:00 noon EST on Fridays. Ship on dry ice.

Clinical Info

Assay range: 112 copies/mL to 1 x 10(8) copies/mL. HHV-7 is detectable in a variety of transplant settings, both HSCT and solid organ. Direct effects of HHV-7 include fever, rash, myelosuppression, encephalitis, and pneumonitis. Potentially more important are the indirect effects HHV-7 has on CMV disease, invasive fungal disease, and allograft dysfunction. Quantitative HHV-7 DNA PCR can be used to document the presence of the virus as well as track the course of infection. The primers and probes used in this assay are specific for known strains of HHV-7 based on similarity search algorithms. Additionally, no cross reactivity was detected when tested against adenoviruses, BKV, CMV, EBV, HSV-1, HSV-2, HHV-6 variant A, HHV-6 variant B, HHV-8, JCV, parvovirus B19, SV-40, and VZV.