CD19 Count




Test Mnemonic

ABS19

CPT Codes

  • 86355 - QTY (1)
  • 85048 - QTY (1)

LOINC ®

8116-6, 8117-4, 26464-8

Aliases

  • CD19

Includes

  • CD19%
  • CD19 absolute number

Performing Laboratory

Cleveland Clinic Laboratories

FDA Category

Analyte Specific Reagent


Specimen Requirements

Volume Type Container Collect Temperature Transport Temperature Special Instructions
4 mLWhole bloodEDTA (Lavender)AmbientAmbientDraw one 2 ml EDTA tube.

Stability

Environmental Condition Description
AmbientMaintain at room temperature when transporting to laboratory. Specimen stability is < 72 hours old. Samples >72 hours old will be rejected.

Days Performed

Mon - Sat

Turnaround Time

1 - 2 days

Reference Range

CD19+ B Cell %
Sex Age From Age To Type Range Range Unit
 5 Years99 YearsNormal5 - 22%
CD19+ B Cell No.
Sex Age From Age To Type Range Range Unit
 5 Years99 YearsNormal75 - 660cells/uL
CD3-CD19+ B Cell #
Sex Age From Age To Type Range Range Unit
~  Months60 MonthsNo normal Pediatric ranges for CD3-CD19+ B Cellscells/uL
CD3-CD19+ B Cell %
Sex Age From Age To Type Range Range Unit
~  Months60 MonthsNo normal Pediatric ranges for CD3-CD19+ B Cells%

Special Info

4ml Lavender (EDTA). Minimum Volume (2ml). store at room temperature. No sharing.

Clinical Info

This test is used for monitoring B-cell targeted therapy.

Clinical Limitation

This test is used for CD19 positive B-cells. It is not meant for enumeration of T-cells or NK cells.

Clinical Reference

CD19+ B cell % 5-22 CD19+ B cell # 75-660 No pediatric ranges for CD19.