Copper, Urine Random




Test Mnemonic

UCOPR

CPT Codes

  • 82525 - QTY (1)

LOINC ®

5632-5

Performing Laboratory

Cleveland Clinic Laboratories

FDA Category

Laboratory Developed Test


Specimen Requirements

Volume Type Container Collect Temperature Transport Temperature Special Instructions
10 mLUrine, randomClean container AmbientDo not allow specimen to come into contact with metal or rubber.

Minimum Specimen Requirements

Volume Type Container Collect Temperature Transport Temperature Special Instructions
5 mL     

Stability

Environmental Condition Description
Ambient30 Days
Refrigerated30 Days
Frozen30 Days

Days Performed

Wed

Turnaround Time

1 - 8 days

Methodology

Name Description
Inductively Coupled Plasma / Mass Spectrometry (ICP-MS) 

Reference Range

Copper, Urine Random
Sex Age From Age To Type Range Range Unit
   Years99 YearsNormal< 6.0ug/dL

Special Info

10 mL random urine collected in clean polypropylene container with no metal caps, glued inserts or preservatives. Do not allow specimen to come into contact with metal or rubber.

Clinical Info

Diagnosis of Wilson's Disease